The device manufacturer experienced failures of devices where parts of the pins were no longer functional. Optical microscopy revealed cracks in the top surface passivation layer for the failed devices. One explanation was that ionic contaminants, possibly present on the outermost surface, migrated through these cracks and caused breakdown in the device. Comparative analysis of the surface of good and failed devices was carried using ToFSIMS to determine the presence, or otherwise, of ionics and find a possibly cause for the failures. | Figure 1. ToFSIMS spectra of the surfaces of a control device (top) and a failed device (below). | The ToFSIMS spectra indicated that the surface of control and failed devices were relatively similar with the detection, in both cases, of low levels of ionic contaminants and also organic residues. Although the migration of ionic contaminants through the crack was one possibility for failure of the devices, an alternative possibility was also discovered. Careful examination of the high mass resolution data showed an unexpected presence of copper on the surface of the failed devices. Case Study Two - Analysis of Bond Pad Areas on Devices Device samples, demounted from their packaging, were submitted for analysis following moisture induced stress testing. Failed devices showed areas of contamination or corrosion product on and adjacent to bond pad areas around the perimeter of the device, which were characterised by SIMS imaging. Equivalent areas of control devices were also analysed for comparison purposes. Mass spectral analysis and SIMS imaging (see selected images below) showed, for the failed device, the presence of aluminium and silicon oxides on and around the bond pad regions. With evidence from the chemical images (in particular Al) which matched the optically observed dentritic structures around the bond pads, these species were strongly suspected to correspond to corrosion products. In addition, antimony, sodium, potassium, chromium and iron residues were also found to be associated with the oxide-rich areas and believed to have participated in the corrosion process. For the control device, analyses also revealed evidences for the early stages of corrosion in bond pad areas. The corrosion mechanism was interpreted as the result of the presence of two dissimilar metals (e.g. Al, Sb, Cr or Fe), electrolytes (Na, K, Ca and probably Cl) and moisture. The occurrence and concentration of the corrosion product around the perimeter of the device suggested that moisture ingress had occurred though the packaging. | Figure 2. Mass spectral and SIMS imaging of the control sample (left) and failed device (right). | |
<< Home